RG-S6980-128DC – 128-Port 200GE Data Center Fixed Core Switch

High-density 200GE fixed switch, support for 200GE optical transceivers

Models
Series
Highlight Features
  • High-density 200GE switch with 128 x 200GE QSFP56 ports housed in a 4-RU enclosure
  • Hardware-level redundancy, ensuring service continuity and preventing network downtime
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry-based network monitoring and automated O&M, making management easy and efficient
Sales Enquiry
Features

RG-S6980-128DC – 128-Port 200GE Data Center Core Switch

The high-speed and high-density core switch provides 128 x 200GE QSFP56 ports housed in a 4-RU enclosure,
delivering scalable, high-performance, and high-bandwidth services for large-scale DCI networks.

Ports

Dimensions

Hardware-Level Redundancy, Ensuring Service Continuity and Preventing Network Downtime

Hot-Swappable Redundant Power Modules

Hot-Swappable Redundant Fan Modules

The switch supports 2+2 power redundancy, enables failover in seconds, and ensures network connectivity during power replacement. This provides dual protection for links.

Lossless Ethernet, Ensuring Zero Packet Loss During RDMA E2E Communication

With the RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU load
and addresses network latency issues.
PFC and ECN are leveraged to implement intelligent data exchange and eliminate packet loss, ensuring lossless transmission of data.

Telemetry-based Network Monitoring and Automated O&M, Making Management Easy and Efficient

The switch enabled with telemetry provides a comprehensive view of data status and hierarchy.
The switch proactively collects and pushes information to provide sub-second-level network monitoring in real time,
making network management more efficient and accurate.

Specifications

Hardware Specifications

System

RG-S6980-128DC

Ports

128 x 200GE ports (QSFP56)

Expansion Modules

Not supported

Power Modules

Four power module slots, supporting 2+2 redundancy

Fan Modules

Eight fan module slots, supporting 7+1 redundancy

Management Ports

One management port, one console port, and one USB port, compliant with the USB2.0 standard

Switching Capacity

51.2 Tbps

Packet Forwarding Rate

10,300 Mpps

Dimensions and Weight

Dimensions

(W x D x H)

442 mm x 760 mm x 175 mm (17.40 in. x 29.92 in. x 6.89 in., 4 RU)

Net Weight

39.65 kg (87.41 lbs., including eight fan modules and four power modules)

Power Supply and Consumption

Maximum Power Consumption

2,550 W

AC

AC input:

Rated voltage range: 100 V AC to 127 V AC

Frequency: 50 Hz to 60 Hz

Maximum rated input current: 12 A

Rated voltage range: 200 V AC to 240 V AC

Frequency: 50 Hz to 60 Hz

Maximum rated input current: 8 A

High-Voltage DC

Voltage: 240 V DC

Maximum rated input current: 6.5 A

Environment and Reliability

Operating temperature

0°C to 40°C (32°F to 104°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

10% RH to 90% RH (non-condensing)

Storage humidity

5% RH to 95% RH (non-condensing)

Altitude

0 m to 1,800 m (0 ft. to 5,905.51 ft.)

* indicates that the feature will be available in the future.

Software Specifications

Software Specifications

RG-S6980-128DC

Layer 2 Protocols

IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), jumbo frame (9 KB)

IPv4 Features

BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, PBR, routing policy, ECMP, WCMP, VRRP

IPv6 Features

Neighbor discovery, ICMPv6, path MTU discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMPv6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS, static routing, ECMP routing, PBR, OSPFv3, RIPng, BGP4+

Data Center Features

PFC, ECN

RDMA

VXLAN, BGP-EVPN

PFC deadlock prevention

* AI ECN

* ECN overlay

RALB, AILB

Visualization

 

Collecting data including basic switch information, real-time RoCE buffer state, interface-based QoS queue and real-time interface utilization, ECN and PFC events, and media side SNR* through telemetry

gRPC

sFlow

QoS

802.1p, DSCP, and ToS mapping

ACL-based traffic classification
Priority marking and re-marking
Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding

Hgh Availability Design

GR for RIP/OSPF/BGP, BFD, REUP, Rapid Link Detection Protocol (RLDP), 2+2 power redundancy, fan redundancy, and hot swappable line cards and power modules

Security Features

Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, Telnet login from specified IP addresses, broadcast packet suppression, and hierarchical user management

Management Mode

SNMP v1/v2/v3, Telnet, console, MGMT, RMON, SSH v1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and overheat alarm

Other Protocols

DHCP client, DHCP relay, DHCP server, DNS client, proxy ARP, and syslog

* indicates that the feature will be available in the future.

Show More
Resources All Resources
Learn about Products or Solutions
Order Information

Chassis, Fan Modules, and Power Modules

Model

Description

RG-S6980-128DC

128 x 200GE ports, four power module slots, eight fan module slots

PSA1300CRPS-F-RJ

Hot swappable power module, 2+2 redundancy, and front-to-rear airflow

FAN12K8080-F-RJ

Hot swappable fan module, 7+1 redundancy, and front-to-rear airflow

 

100GBASE Optical Transceivers

Model

Description

100G-QSFP-iLR4-SM1310

100G iLR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

100G-QSFP-LR4-SM1310

100G LR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

100G-QSFP-SR-MM850

100G SR transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF

100G-QSFP-ER4-SM1310

100G ER4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF

100G-AOC-1M

100G AOC cable, QSFP28 form factor, 1 m (3.28 ft.)

100G-AOC-5M

100G AOC cable, QSFP28 form factor, 5 m (16.40 ft.)

100G-AOC-10M

100G AOC cable, QSFP28 form factor, 10 m (32.81 ft.)

 

200GBASE Optical Tranceivers

Model

Description

200G-Q56-SR4-MM850(D)

200G SR4 transceiver, QSFP56 form factor, MPO-12/APC, 850 nm, 100 m (328.08 ft.) over OM4 MMF, in compliance with CMIS, applied to the switch side.

200G-Q56-SR4-MM850

200G SR4 transceiver, QSFP56 form factor, MPO-12/APC, 850 nm, 100 m (328.08 ft.) over OM4 MMF, in compliance with SFF-8636, applied to the server side. 

Show More
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Contacte-nos

Contacte-nos

How can we help you?

Contacte-nos

Get an Order help

Contacte-nos

Get a tech support