Compare Products

Hide

Clear All

VS

RG-S5760C-24GT8XS-X Switches - 1
RG-S5760C-24GT8XS-X Switches - 2
RG-S5760C-24GT8XS-X Switches - 3
RG-S5760C-24GT8XS-X Switches - 4
RG-S5760C-24GT8XS-X Switches - 5
RG-S5760C-24GT8XS-X Switches - 6
RG-S5760C-24GT8XS-X Switches - 7
RG-S5760C-24GT8XS-X Switches - 8
RG-S5760C-24GT8XS-X Switches - 9
RG-S5760C-24GT8XS-X Switches - 10
RG-S5760C-24GT8XS-X Switches - 11
RG-S5760C-24GT8XS-X Switches - 12
RG-S5760C-24GT8XS-X Switches - 1
RG-S5760C-24GT8XS-X Switches - 2
RG-S5760C-24GT8XS-X Switches - 3
RG-S5760C-24GT8XS-X Switches - 4
RG-S5760C-24GT8XS-X Switches - 5
RG-S5760C-24GT8XS-X Switches - 6
RG-S5760C-24GT8XS-X Switches - 7
RG-S5760C-24GT8XS-X Switches - 8
RG-S5760C-24GT8XS-X Switches - 9
RG-S5760C-24GT8XS-X Switches - 10
RG-S5760C-24GT8XS-X Switches - 11
RG-S5760C-24GT8XS-X Switches - 12
Picture

RG-S5760C-24GT8XS-X 24-Port GE Electrical Layer 3 Enterprise-Class Core or Aggregation Switch, Eight 10G Uplink Ports

Aggregation switch for large-sized networks, or core switch for small and medium-sized networks

Models
Series
Highlight Features
  • Rich port types, 24 x 1000 Mbps Ethernet ports, and eight 10G optical ports for uplink
  • Hardware redundancy, guaranteed service continuity and network connectivity
  • VSU virtualization, flexible networking and high performance
  • Layer 3 routing control, adaptive to multiple services, efficient and guaranteed data transmission
  • Network security policies, real-time monitoring, CPP and NFPP, delivering enhanced network robustness
  • SNMP, RMON, Syslog, USB log backup features, CLI, Eweb, telnet and other management modes, easy network maintenance
Sales Enquiry
Key Specification View More
Features

Layer 3 GE Core & Aggregation Switch S5760C-24GT8XS-X

Aggregation switch for small and medium-sized campus networks, with eight 10G uplink optical ports for high-speed data transmission; 24 x 1000 Mbps Ethernet ports with auto-negotiation, providing high-speed network experience for short-distance services. Core switch for small and medium-sized enterprise networks, with high scalability, efficiency, and manageability, and device-level and link-level reliabilities for stable connectivity.

Hardware Redundancy, Guaranteed Service Continuity and Network Connectivity

Hardware-level Boot Redundancy

Hot-Swappable Power Modules

Two Flash chips are used to store the system boot program for hardware-level boot redundancy, avoiding device failure caused by a failed Flash chip.

VSU Virtualization, Flexible Networking and High Performance

Millisecond Failover

High Scalability

Simplified Networking

The VSU connects to peripherals through an aggregate link, realizing service switching in milliseconds upon a failure.

Layer 3 Routing Control, Adaptive to Multiple Services, Efficient and Guaranteed Data Transmission

IPv4 and IPv6 Protocols

Abundant Multicast Protocols

Static and Dynamic Routing

The hardware supports dual stack for high-speed switching, catering to the requirements of campus network transition from IPv4 protocol to IPv6 protocol, with significant improvement in address table capacity and network security.

Network Security Policies and Real-Time Monitoring, Delivering Enhanced Network Robustness

CPP

NFPP

Large amounts of data from different sources are handled by CPP first to prevent direct attacks on the CPU, ensuring CPU stability under high usage, and achieving significant improvement in the device's security performance.

Managed by the INC Controller to Achieve Easy and Efficient O&M Management

The switch automatically completes registration and
configuration after it accesses the all-optical network, achieving
plug and play, no commissioning and fast onboarding.
A switch can be flexibly replaced based on service needs
without reconfiguration. Service ports supports auto-sensing,
achieving automatic O&M.

Fast Onboarding

Zero Touch Replacement

Specifications

Hardware Specifications

RG-S5760C-24GT8XS-X

RG-S5760C-48GT4XS-X

RG-S5760C-24SFP8GT8XS-X

RG-S5760C-48SFP4XS-X

RG-S5760C-48GT4XS-HP-X

Interface Specifications

Fixed port

24 x 10/100/1000 Mbps electrical ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 2 x power supply module slots

48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 2 x power supply module slots

24 x 1000 Mbps SFP ports (Ports 1-16 are 100/1000 Mbps SFP ports), 8 x 10/100/1000 Mbps combo ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 2 x power supply module slots

48 x 1000 Mbps SFP ports, 4 x 1GE/10GE SFP+ ports, 3 x modular fans, 2 x power supply module slots

48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 2 x power supply module slots, supporting PoE/PoE+

Fan module

Two built-in fan modules

Fan speed regulating and fault alarms

Three pluggable fan modules

Two pluggable fan modules

Power module

Two power modules

The switch can be powered on by either one or dual power modules. If both power modules are used, the switch works in the power redundancy mode.

Management port

One MGMT port, one console port, and one USB port, compliance with the USB2.0 standard

Expansion slot

Two expansion slots are reserved for expansion modules and supervisor modules. One expansion slot is reserved on the RG-S5760C-48GT4XS-HP-X and RG-S5760C-48SFP4XS-X.

System Specifications

System packet forwarding rate *

614 Mpps

586 Mpps

614 Mpps

586 Mpps

586 Mpps

System switching capacity *

826 Gbps

787 Gbps

826 Gbps

787 Gbps

787 Gbps

Number of MAC addresses

64,000

64,000

64,000

64,000

64,000

ARP table size

24,000

24,000

24,000

24,000

24,000

Number of IPv4 unicast routes

24,000

24,000

24,000

24,000

24,000

Number of IPv4 multicast routes

4,000

mmu-enhance: 3,000

4,000

mmu-enhance: 3,000

4,000

mmu-enhance: 3,000

4,000

mmu-enhance: 3,000

4,000

mmu-enhance: 3,000

Number of IPv6 unicast routes

14,000

14,000

14,000

14,000

14,000

Number of IPv6 multicast routes

2,000

mmu-enhance: 1,500

2,000

mmu-enhance: 1,500

2,000

mmu-enhance: 1,500

2,000

mmu-enhance: 1,500

2,000

mmu-enhance: 1,500

Number of ACEs

In: 7,000

Out:1,500

Number of IGMP groups

4,000

Number of MLD groups

1,000

Number of VSU members

4

Dimensions and Weight

Dimensions (W x D x H)

440 mm x 340 mm x 44 mm (17.32 in. x 13.39 in. x 1.73 in.)

442 mm x 420 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.)

Weight

4.4 kg (9.70 lbs)

4.5 kg (9.92 lbs)

4.3 kg (9.48 lbs)

5.3 kg (11.68 lbs)

5.5 kg (12.13 lbs)

CPU and Storage

CPU

1.2 GHz dual-core CPU

Storage

Flash memory: 4 GB

SDRAM: 1 GB

Flash memory: 4 GB

SDRAM: 2 GB

Data packet buffer

4MB

Power and Consumption

Maximum power consumption

< 60 W (excluding expansion modules)

< 85 W (including expansion modules)

< 70 W (excluding expansion modules)

< 95 W (including expansion modules)

< 77 W (excluding expansion modules)

< 102 W (including expansion modules)

< 105 W (excluding expansion modules)

< 125 W (including expansion modules)

Without PoE load: ≤ 110 W

With PoE full load: ≤ 1,590 W

Maximum output power

RG-PA70IB: 70 W

RG-PA150I-F: 150 W

RG-PA150IB-F: 100 V to 240 V, 150 W

RG-PD150IB-F: 48 V DC to 60 V DC, 150 W

RG-PA70IB: 70 W

RG-PA150I-F: 150 W

RG-PA150IB-F: 100 V to 240 V, 150 W

RG-PD150IB-F: 48 V DC to 60 V DC, 150 W

RG-PA150I-F: 150 W

RG-PA150IB-F: 100 V to 240 V, 150 W

RG-PD150IB-F: 48 V DC to 60 V DC, 150 W

RG-PA150I-F: 150 W

RG-PA150IB-F: 100 V to 240 V, 150 W

RG-PD150IB-F: 48 V DC to 60 V DC, 150 W

RG-PA600I-P-F: 600 W (PoE: 370 W)

RG-PD600I-P-F: 600 W (PoE: 370 W)

RG-PA1000I-P-F: 176 V AC to 290 V AC, 1000 W; 90 V AC to 176 V AC, 930 W (PoE: 740 W)

Rated input voltage

AC input

Rated voltage range: 100 V to 240 V

Frequency: 50 Hz/60 Hz

HVDC input:

Rated voltage range: 240 V

LVDC input:

Rated voltage range: 48 V DC to 60 V DC

AC input

Rated voltage range: 200 V to 240 V

Frequency: 50 Hz/60 Hz

DC input:

Rated voltage range: 48 V to 60 V

AC input

Rated voltage range: 200 V to 240 V

Frequency: 50 Hz/60 Hz

DC input:

Rated voltage range: 48 V to 60 V

Maximum input voltage

AC input

Maximum voltage range: 90 V to 264 V

HVDC input:

Maximum voltage range: 192 V to 288 V

LVDC input:

Maximum voltage range: 36 V DC to 75 V DC

AC input

Maximum voltage range: 176 V to 264 V

DC input:

Maximum voltage range: 38 V to 75 V

AC input

Maximum voltage range: 90 V to 264 V

DC input:

Maximum voltage range: 36 V to 75 V

Environment and Reliability

MTBF

120 years

110 years

94 years

90 years

95 years

Primary Airflow

Air intake from left and front panel, and air exhaust from right

Front-to-rear airflow

Operating temperature

0°C to 45°C (32°F to 113°F)

V1.X+M5000X4XS2CQ: 0 to 40°C (32°F to 104°F)

0°C to 45°C (32°F to 113°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

10% to 90% (non-condensing)

Storage humidity

5% to 95% (non-condensing)

Operating altitude

0 m to +5,000 m (0 ft. to +16404.20 ft.)

Operating noise

45°C (113°F): 56.2 dB

45°C (113°F): 57.9 dB

45°C (113°F): 57.1 dB

27°C (80.6°F): 50 dB

45°C (113°F): 65 dB

27°C (80.6°F): 53 dB

45°C (113°F): 68 dB

Interface surge protection

Power port: 6 kV

Telecom port: 10 kV (MGMT port: 4 kV)

 * System packet forwarding rate means the system's packet forwarding rate

* System switching capacity means the system's switching capacity



Software Specifications

RG-S5760-X Series

Ethernet switching

Jumbo frame (maximum length: 9,216 bytes)

IEEE 802.1Q (supporting 4K VLANs)

Voice VLAN

Super-VLAN and private VLAN

MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment

GVRP

Basic QinQ and selective QinQ

STP, RSTP, and MSTP

ERPS (G.8032)

LLDP/LLDP-MED

LACP (IEEE 802.3ad)

IP service

ARP

DHCP client, DHCP relay, and DHCP server

DHCP snooping

DNS

DHCPv6 client, DHCPv6 server, and DHCPv6 relay

DHCPv6 snooping

Neighbor Discovery (ND) and ND snooping

IPV6 addressing, ICMPv6, Stateless Address Auto-configuration (SLAAC), and path MTU discovery

IP routing

Static routing

RIP and RIPng

OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6

BGP4 and BGP4+

ECMP

IPv4 and IPv6 VRF

IPv4 and IPv6 PBR

Multicast

IGMP v1/v2/v3 and IGMP proxy

IGMP v1/v2/v3 snooping

IGMP filtering and IGMP fast leave

PIM-DM, PIM-SM, and PIM-SSM

MSDP

MLD snooping v1/v2

PIM-SMv6 and PIM-SSM v6

MPLS

MPLS L3VPN

ACL and QoS

Standard IP ACLs

Extended IP ACLs

Extended MAC ACLs

Time-based ACLs

Expert-level ACLs

ACL80

IPv6 ACL

ACL redirection

Port traffic identification

Port traffic rate limiting

Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ

Congestion avoidance: tail drop, RED, and WRED

802.1p/DSCP/ToS traffic classification

Eight priority queues per port

Security

AAA

RADIUS and TACAS+

Port-based and MAC address-based 802.1X authentication

Web authentication

HTTPS

SSHv1 and SSHv2

Global IP-MAC binding

Port isolation and port security

IP source guard

SAVI

CPP and NFPP

Strict and loose RPF

uRPF ignoring default routes

3-tuple binding (IP address, MAC address, and port)

3-tuple binding (IPv6 address, MAC address, and port)

Filtering of unauthorized MAC addresses

MAC address bypass (MAB) authentication

Portal authentication and Portal 2.0 authentication

ARP check

Dynamic ARP Inspection (DAI)

ARP packet rate limiting

Gateway ARP anti-spoofing

Broadcast storm suppression

Hierarchical management of administrators and password protection

AAA for device login management

MAC Authentication Bypass (SSH)

BPDU guard

Port protection

Reliability

REUP, RLDP, and DLDP

IPv4 VRRP v2/v3 and IPv6 VRRP

GR for RIP, OSPF, BGP, and other routing protocols

BFD

Link tracing, fault notification, and remote loopback based on 802.3ah (EFM)

1+1 power module redundancy

Hot swapping of power modules and cables

3-level fan speed adjustment

Fan fault alarm

Device virtualization

VSU

Forwarding mode

Store and forwarding

NMS and maintenance

SPAN, RSPAN, and ERSPAN

sFlow

NTP and SNTP

FTP and TFTP

SNMP v1/v2c/v3

RMON (1, 2, 3, 9)

SSHv1 and SSHv2

Syslog

NETCONF

CWMP (TR-069)

gRPC

CLI (Telnet/Console), SNMP over IPv6, IPv6 MIB support for SNMP, SSHv6, Telnet v6, FTP/TFTP v6, DNS v6, NTP for IPv6, and Traceroute v6

PoE

RG-S5760C-48GT4XS-HP-E:

IEEE 802.3af and 802.3at, uninterruptible power supply upon hot start, and port priority

VXLAN

With VXLAN, a Layer 2 logical network can be built based on a Layer 3 network through software upgrade.



Show More
Resources All Resources
Learn about Products or Solutions
Software and Configuration
Order Information

Power Modules

Model

Description

RG-S5760C-24GT8XS-X

24 x 10/100/1000 Mbps electrical ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots

Purchase at least one RG-PA150IB-F module.

RG-S5760C-48GT4XS-X

48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.)

RG-S5760C-24SFP8GT8XS-X

24 x 10/100/1000 Mbps SFP ports (Ports 1-16 are 100/1000 Mbps SFP ports), 8 x 10/100/1000 Mbps combo ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.)

RG-S5760C-48SFP4XS-X

48 x 1000 Mbps SFP ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x modular fans, 2 x power module slots

Purchase at least one RG-PA150IB-F module.

RG-S5760C-48GT4XS-HP-X

48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x modular fans, 2 x power module slots

Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F/RG-PD600I-P-F module.

M5000X-4XS2CQ

4 x 10GE SFP+ ports and 2 x 100GE QSFP28 ports

RG-PA150IB-F

150 W AC power module

RG-PA600I-P-F

600 W PoE AC power module

RG-PA1000I-P-F

1000 W PoE AC power module

RG-PD600I-P-F

600 W PoE DC power module

 

Optical Modules

Model

Description

Mini-GBIC-GT

1000BASE-GT mini GBIC module

MINI-GBIC-SX-MM850

Single-port 1000BASE-SX mini GBIC module (LC connector)

MINI-GBIC-LX-SM1310

Single-port 1000BASE-LX mini GBIC module (LC connector)

MINI-GBIC-LH40-SM1310

Single-port 1000BASE-LH mini GBIC module (LC connector), supporting a transmission distance of 40 km (24.85 miles)

MINI-GBIC-ZX50-SM1550

Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 50 km (24.85 miles)

MINI-GBIC-ZX80-SM1550

Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 80 km (24.85 miles)

MINI-GBIC-ZX100-SM1550

1000BASE-ZX mini GBIC module, supporting a transmission distance of 100 km (62.14 miles)

XG-SFP-SR-MM850

10GE LC module (62.5/125 μm: 33 m (108.27 ft.); 50/125 μm: 66 m (216.54 ft); transmission for 300 m (984.25 ft.) when modal bandwidth is 2000 MHz*km), applicable to SFP+ ports

XG-SFP-LR-SM1310

10GE LC interface module (1310 nm), 10 km (6.21 miles), applicable to SFP+ ports

XG-SFP-ER-SM1550

10GE LC interface module (1550 nm), 40 km (24.85 miles), applicable to SFP+ ports

XG-SFP-AOC1M

10GE SFP+ optical cable, 1 m (3.28 ft.), including one cable and two interface modules

XG-SFP-AOC3M

10GE SFP+ optical cable, 3 m (9.84 ft.), including one cable and two interface modules

XG-SFP-AOC5M

10GE SFP+ optical cable, 5 m (16.40 ft.), including one cable and two interface modules

Show More
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Contacte-nos

Contacte-nos

How can we help you?

Contacte-nos

Get an Order help

Contacte-nos

Get a tech support