Both data center features and campus network features are supported
Rich data center features are supported to ensure network integration and virtual switching
The RG-S6220 series is applicable to scenarios such as data centers, campus networks, and MANs based on service requirements
RG-S6220-48XS6QXS-H
RG-S6220-48XT6QXS-H
RG-S6220-32QXS-H
A single switch provides a maximum of 48 fixed 10GE ports and 6 fixed 40GE ports, and all of the ports can support the line rate.
10GBase-T electrical ports are supported to connect to 10G electrical servers, ensuring cost-effective networking.
The RG-S6220-32QXS-H supports 32 fixed 40GE ports ensuring high-speed data center networking.
The VSU2.0 technology can be used to virtualize multiple core switches into one logical device, ensuring network resource pooling.
A maximum of nine devices can be virtualized into one logical device, to improve network reliability, ensure load balancing between data links,
and implement unified management across the whole logical unit.
The VEPA technology is supported, which diverts traffic of virtual servers to physical switches, improving the security and
traffic controllability of the virtual servers.
Security policies can be migrated with VMs, ensuring automatic following of security policies during VM migration.
Layer-2 networking, meeting VM migration service requirements
EVPN VXLAN, ensuring multi-tenant isolation
Anycast gateway, ensuring optimal forwarding path
Tolly Group, an international third-party authority for testing and certification,
proves the superb performance of RG-S6220 series data center 10G TOR switches.
A single switch provides a maximum of 48 fixed 10GE ports and 6 fixed 40GE ports, and all of the ports can support the line rate.
10GBase-T electrical ports are supported to connect to 10G electrical servers, ensuring cost-effective networking.
The RG-S6220-32QXS-H supports 32 fixed 40GE ports ensuring high-speed data center networking.
A single switch provides a maximum of 48 fixed 10GE ports and 6 fixed 40GE ports, supporting the full line rate.
RG-S6220-48XS6QXS-H provides 48 fixed 10GE SFP ports and six fixed 40GE ports.
RG-S6220-48XT6QXS-H provides 48 fixed 10GBase-T electrical ports ports and six fixed 40GE ports.
10GBase-T electrical ports are supported to connect to 10G electrical servers, ensuring cost-effective networking.
10GE networks can be built with only RJ-45 network cables. The cost is low, and the power consumption over ports is lower than that of conventional
The VSU2.0 technology can be used to virtualize multiple core switches into one logical device, ensuring network resource pooling.
A maximum of nine devices can be virtualized into one logical device, to improve network reliability, ensure load balancing between data links,
and implement unified management across the whole logical unit.
The VEPA technology is supported, which diverts traffic of virtual servers to physical switches, improving the security and
traffic controllability of the virtual servers.
Security policies can be migrated with VMs, ensuring automatic following of security policies during VM migration.
The VSU2.0 technology can be used to virtualize multiple core switches into one logical device, ensuring network resource pooling.
A maximum of nine devices can be virtualized into one logical device to improve network reliability, ensure load-balancing between data links,
and meanwhile implement unified management of the entire logical unit.
The VEPA technology is supported, which diverts traffic of virtual servers to physical switches,
improving the security and traffic controllability of the virtual servers.
Security policies can be migrated with VMs, ensuring automatic following of security policies during VM migration.
Layer-2 networking, meeting VM migration service requirements
EVPN VXLAN, ensuring multi-tenant isolation
Anycast gateway, ensuring optimal forwarding path
VXLAN ensures layer-2 networking across IP networks through UDP tunnels, ensuring VM migration between two TOR switches
The control plane protocol MP-BGP EVPN can automatically synchronize host information among TOR switches. It provides transmission
support for large-scale VXLAN deployment and meets VM migration service requirements
Tenant data can be transmitted through different TOR switches, and different tenants or services can be logically isolated using EVPN VXLAN.
The Anycast gateway is supported. The server directly connects to the TOR switch, and each TOR switch can serve as a gateway,
so that the service flow forwarding path provided by the server to external devices is optimal.
Tolly Group, an international third-party authority for testing and certification,
proves the superb performance of RG-S6220 series data center 10G TOR switches.
Tolly Group, an international third-party authority for testing and certification,
proves the superb performance of RG-S6220 series data center 10G TOR switches.
The TRILL technology of the N18000 and S6220 series switches are used to build two layer-2 networks,
so that the N18000 L2GRE technology is used to build a layer-2 network between two data centers.
Model | RG-S6220-48XS6QXS-H-AC | RG-S6220-48XT6QXS-H-AC |
Ports | 48 fixed 10G SFP+ ports | 48 fixed 10GBASE-T ports (RJ 45) |
Modular Power Slots | 2 |
|
Fan Slots | 3 |
|
Management Ports | 1 console port 1 USB 2.0 port 1 mini USB console port |
|
Switching Capacity | 2.56Tbps |
|
Packet Forwarding Rate | 1,080Mpps |
|
Port Buffer | 16MB |
|
RAM | 2GB |
|
ARP Table | Up to 40K |
|
MAC Address | Up to 96K |
|
Routing Table Size (IPv4/IPv6) | 12K/6K |
|
Multicast Entries (IPv4/IPv6) | Up to 16K |
|
ACL Entries | Up to 8K |
|
VLAN | 4K VLANs, Port-based VLAN, MAC-based VLAN, Super VLAN, Protocol-based VLAN, Private VLAN, IP subnet-based VLAN, GVRP |
|
QinQ | Basic QinQ, Flexible QinQ |
|
Link Aggregation | Support LACP |
|
Port Mirroring | Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN |
|
Spanning Tree Protocols | IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, Loop guard, Root guard,Spanning Tree Root Guard(STRG) |
|
DHCP | DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP relay |
|
Multiple Spanning Tree Protocol (MSTP) Instances | 64 (not include default 0) |
|
Maximum Aggregation Port (AP) | Up to 256 |
|
Virtual Routing and Forwarding (VRF) Instances | Up to 2K |
|
Data Center Unified Network Features | Virtualization: |
|
VSU (Virtual Switch Unit) | Support (up to 4 stack members) |
|
L2 Features | MAC, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast storm control, IGMP v1/v2/v3 snooping, IGMP filter, IGMP fast leave, MLD snooping, DHCP, Jumbo frame, RLDP, LLDP |
|
Layer 2 Protocols | IEEE802.3 (10BASE-T), IEEE802.3u (100BASE-T), IEEE802.3z (1000BASE-X), IEEE802.3ab (1000BASE-T), IEEE802.3ae (10GBASE-T), IEEE802.3an (10GBASE-T), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (link aggregation), IEEE802.1p, IEEE802.1x, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP snooping, Jumbo Frame (9Kbytes), IEEE802.1ad (QinQ and flexible QinQ), GVRP |
|
Layer 3 Features | ARP, IPv4/v6, PBRv4/v6 |
|
Layer 3 Protocols (IPv4) | BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM routing, Policy-based routing, Route-policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/DM, MSDP, Any-RP, ISIS |
|
IPv4 Features | Ping, Traceroute, Equal-cost routing, URPF, IPIP, GRE tunnel, VRF |
|
IPv6 Features | Static routing Equal-cost routing, Policy-based routing, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, Manual tunnel, Auto tunnel, IPv4 over IPv6 tunnel, ISATAP tunnel |
|
Basic IPv6 Protocols | ND, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping /Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, VRRP for IPv6,, ISISv6 |
|
IPv6 Routing Protocols | Static routing, Equal-cost routing, Policy routing, RIPng, OSPFv2/v3, BGP4+, IS-IS |
|
IPv6 Tunnel Features | Manual tunnel, Auto tunnel, 6over4 manual tunnel, 6to4 auto tunnel, ISATAP, IPv4 over IPv6 tunnel, IPv6 over IPv6 tunnel, GRE tunnel |
|
Multicast | IGMP v1/v2/v3, IGMP proxy, MSDP, PIM-DMv4 (PIM-DM), PIM-SMv4 (PIM-SM, PIM-SSM), PIM-SM v6, MLD, MLD Proxy |
|
ACL | Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL |
|
QoS | EXP priority mapping based on 802.1p, DSCP, TOS and IP Precedence; ACL traffic classification; Priority marking/remarking; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WRR, and SP+DRR |
|
Reliability | VSU (virtualization technology for virtualizing multiple devices into 1); GR for OSPF/IS-IS/BGP; BFD detection; REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; 2+1 fan redundancy; Hot-swappable line cards and power modules,Dynamic ARP Inspection(DAI), |
|
Security | Network Foundation Protection Policy (NFPP); CPU Protection (CPP); DoS protection; Detection of unauthorized data packets; Data encryption; IP source guard; RADIUS / TACACS+; IPv4 / IPv6 ACL packet filtering based on standard or extended VLANs; Plaintext authentication and MD5 cipher-text authentication of OSPF, RIPv2, and BGPv4 packets; Telnet login through limited IP addresses and the password mechanism; uRPF; Broadcast packet suppression; DHCP snooping,DHCP otpion 82,; Anti-gateway ARP spoofing; ARP check, |
|
Manageability | SNMP v1/v2c/v3; Telnet; Console; Hardware support RCMI (combo interface for MGMT); RMON; SSHv1/v2; FTP/TFTP for file upload and download management; NTP clock; Syslog; SPAN/RSPAN; sFlow. |
|
Hot Patch | Support |
|
Smart Temperature Control | Auto fan speed adjustment; Fan malfunction alerts; Fan status check |
|
Smart Power Supply | Support power monitor |
|
Other Protocols | DHCP client, DHCP relay, DHCP server, DNS client, UDP relay, ARP proxy, Syslog |
|
Dimensions | 442× 420 × 44 |
|
Rack Height | 1RU |
|
Weight | 9.0 kg (including 3 fan modules and 2 power modules) |
|
MTBF | >200K hours |
|
Power Supply | AC input: |
|
Power Consumption | <200W |
|
Temperature | Operating temperature: 0°C to 50°C |
|
Humidity | Operating humidity: 10% to 90%RH |
The topology diagram of the government and enterprise Active/Active data center and the large-scale Internet data center is shown in figure below:
Typical Application of the RG-S6220H-AC Switch Series
1. Chassis, expansion modules, fans, and power modules
Model | Description |
---|---|
RG-S6220-48XS6QXS-H-AC | S6220-48XS6QXS-H-AC bundle pack, include: RG-S6220-48XS6QXS-H (Qty:1) M6220 FAN – F (Qty: 3) RG-M6220-AC460E-F (Qty: 2) |
RG-S6220-48XT6QXS-H-AC | S6220-48XT6QXS-H-AC bundle pack, include: RG-S6220-48XT6QXS-H (Qty:1) M6220 FAN – F (Qty: 3) RG-M6220-AC460E-F (Qty: 2) |
M6220-FAN-F | Fan Module, front-to-rear airflow |
M6220-FAN II-F | Fan Module, front-to-rear airflow |
RG-M6220-AC460E-F | AC power supply module (front-to-rear airflow) with up to 2 power modules, support 1+1 redundancy, |
RG-M6220-DC460E-F | DC power supply module (front-to-rear airflow) with up to 2 power modules, support 1+1 redundancy |
2. Optional 40G and 10G fiber modules
Model | Description |
40G-QSFP-SR-MM850 | 40G SR Fiber Module for QSFP+ ports, 100m (OM3) / 150m (OM4) (8 cores, 850nm) |
40G-QSFP-LSR-MM850 | 40G SR Fiber Module for QSFP+ ports, 300m (OM3) / 400m (OM4) (8 or 12 cores, 850nm) |
40G-QSFP-LR4-PSM-SM1310 | 40G LR Single-mode 1-to-4 Fiber Module for QSFP+ ports, 10km (LC) (1310nm) |
40G-QSFP-LR4-SM1310 | 40G LR Single-mode Fiber Module for QSFP+ ports, 10km (LC) (2 cores, 1310nm) |
XG-SFP-SR-MM850 | 10G SR Fiber Module for SFP+ ports, 300m |
XG-SFP-LR-SM1310 | 10G LR Fiber Module for SFP+ ports, 10km |
XG-SFP-ER-SM1550 | 10G ER Fiber Module for SFP+ ports, 40km |
XG-SFP-ZR-SM1550 | 10G ZR Fiber Module for SFP+ ports, 80km |
3. Optional 40G and 10G copper cables
Model | Description |
40G-AOC-5M | 40G QSFP+ Optical Stack Cable (included both side transceivers), 5 Meters |
XG-SFP-AOC1M | 10GBASE SFP+ Optical Stack Cable (included both side transceivers) , 1 Meter |
XG-SFP-AOC3M | 10GBASE SFP+ Optical Stack Cable (included both side transceivers), 3 Meter |
XG-SFP-AOC5M | 10GBASE SFP+ Optical Stack Cable (included both side transceivers), 5 Meter |
4. Optical Gigabit modules
Model | Description |
Mini-GBIC-GT | 1000BASE-GT mini GBIC Transceiver |
Mini-GBIC-SX-MM850 | 1000BASE-SX mini GBIC Transceiver (850nm) |
Mini-GBIC-LX-SM1310 | 1000BASE-LX mini GBIC Transceiver (1310nm) |
Mini-GBIC-LH40-SM1310 | 1000BASE-LH mini GBIC Transceiver (1310nm, 40km) |
Mini-GBIC-ZX50-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 50km) |
Mini-GBIC-ZX80-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 80km) |
Mini-GBIC-ZX100-SM1550 | 1000BASE-ZX mini GBIC Transceiver (1550nm, 100km) |